| San-I-Pak's
Auto Series articulating chamber design has been developed in
recognition of 3 major issues concerning the choice of a biohazardous
waste treatment system. The first important issue is safe handling
of the waste, the second issue is equipment capital cost and
the third is operational cost. Of course there are many other
concerns such as efficacy and equipment longevity, so we have
designed the equipment for virtually all concerns with emphasis
on the first three. This equipment has evolved incorporating
suggestions and operational issues from the healthcare industry,
creating the finest technological entry by the most experienced
infectious waste treatment system manufacturing company in the
world today. |
| |
|
|
| |
| The
San-I-Pak
"Auto"
Series sterilizers are designed utilizing multiple chambers
lined up with a common load platform, conveyor, compactor (S,L,XL,C,SC)
and roll-off container. The capacities, configurations and options
are site specific and unlimited. The "Auto" Series
sterilizers offer several means of loading the infectious waste
into the chamber; this can be accomplished via cart dumpers,
conveyor belts, screw augers or manually. This provides the
facility the capability of having an infectious waste treatment
system that virtually eliminates operator handling of infectious
waste. The unit is extremely compact by design and takes up
50% to 60% less space than systems capable of doing half the
volume. The chambers are designed to insure proper load density
for "total kill" sterilization, unlike other systems
currently available. The multiple chamber design of San-I-Pak
systems provides for processing redundancy and a built-in back
up. It is extremely unlikely the entire system would be inoperable.
If one of the many sterilization chambers is being serviced,
the other completely independent chamber can be utilized until
both are operational again. The units are designed for one person
operation and require the least amount of operator handling
of any steam sterilization system available. |
| |
Select
for information on Auto-Series Model Definitions
Select to View Equipment
Photo Gallery
Select to View Sample Designs |
| |
|
| Auto-Series
Models, Specifications & Capacities |
| |
| 230
Series Sterilizer |
Chamber
Size

32" ID x 40" L |
230
Series Models |
| 231 |
232 |
233 |
234 |
235 |
236 |
237 |
238 |
| Number
of Chambers |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
|
Capacity
Per Hour

8 Hour Shift

16 Hour Shift

24 Hour Shift
|
106 |
212 |
318 |
424 |
530 |
636 |
742 |
848 |
| 848 |
1,696 |
2,544 |
3,392 |
4,240 |
5,088 |
5,936 |
6,784 |
| 1,696 |
3,392 |
5,088 |
6,784 |
8,480 |
10,176 |
11,872 |
13,868 |
| 2,544 |
5,088 |
7,632 |
10,176 |
12,720 |
15,264 |
17,808 |
20,352 |
|
| |
| 240
Series Sterilizer |
Chamber
Size

32" ID x 54" L |
240
Series Models |
| 241 |
242 |
243 |
244 |
245 |
246 |
247 |
248 |
| Number
of Chambers |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
|
Capacity
Per Hour

8 Hour Shift

16 Hour Shift

24 Hour Shift
|
160 |
320 |
480 |
640 |
800 |
960 |
1,120 |
1,280 |
| 1,280 |
2,560 |
3,840 |
5,120 |
6,400 |
7,680 |
8,960 |
10,240 |
| 2,560 |
5,120 |
7,680 |
1,240 |
12,800 |
15,360 |
17,920 |
20,480 |
| 3,840 |
7,680 |
11,520 |
15,360 |
19,200 |
23,040 |
26,880 |
30,720 |
|
| |
| 250
Series Sterilizer |
Chamber
Size

32" ID x 66" L |
250
Series Models |
| 251 |
252 |
253 |
254 |
255 |
256 |
257 |
258 |
| Number
of Chambers |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
|
Capacity
Per Hour

8 Hour Shift

16 Hour Shift

24 Hour Shift
|
200 |
400 |
600 |
800 |
1,000 |
1,200 |
1,400 |
1,600 |
| 1,600 |
3,200 |
4,800 |
6,400 |
8,000 |
9,600 |
11,200 |
12,800 |
| 3,200 |
6,400 |
9,600 |
12,800 |
16,000 |
19,200 |
22,400 |
25,600 |
| 4,800 |
9,600 |
14,400 |
19,200 |
24,000 |
28,800 |
33,600 |
38,400 |
|
| |
| 340
Series Sterilizer |
Chamber
Size

38" ID x 55" L |
340
Series Models |
| 341 |
342 |
343 |
344 |
345 |
346 |
347 |
348 |
| Number
of Chambers |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
|
Capacity
Per Hour

8 Hour Shift

16 Hour Shift

24 Hour Shift
|
230 |
460 |
690 |
920 |
1,150 |
1,380 |
1,610 |
1,840 |
| 1,840 |
3,680 |
5,520 |
7,360 |
9,200 |
11,040 |
12,880 |
14,720 |
| 3,680 |
7,360 |
11,040 |
14,720 |
18,400 |
22,080 |
25,760 |
29,440 |
| 5,520 |
11,040 |
16,560 |
22,080 |
27,600 |
33,120 |
38,640 |
44,160 |
|
| |
| 350
Series Sterilizer |
Chamber
Size

38" ID x 67" L |
350
Series Models |
| 351 |
352 |
353 |
354 |
355 |
356 |
357 |
358 |
| Number
of Chambers |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
|
Capacity
Per Hour

8 Hour Shift

16 Hour Shift

24 Hour Shift
|
280 |
560 |
840 |
1,120 |
1,400 |
1,680 |
1,960 |
2,240 |
| 2,240 |
4,480 |
6,720 |
8,960 |
11,200 |
13,440 |
15,680 |
17,920 |
| 4,480 |
8,960 |
13,440 |
17,920 |
22,400 |
26,880 |
31,360 |
35,840 |
| 6,720 |
13,440 |
20,160 |
26,880 |
33,600 |
40,320 |
47,040 |
53,760 |
|
| |
| 460
Series Sterilizer |
Chamber
Size

48" ID x 72" L |
460
Series Models |
| 461 |
462 |
463 |
464 |
465 |
466 |
467 |
468 |
| Number
of Chambers |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
|
Capacity
Per Hour

8 Hour Shift

16 Hour Shift

24 Hour Shift
|
650 |
1,300 |
1,950 |
2,600 |
3,250 |
3,900 |
4,550 |
5,200 |
| 5,200 |
10,400 |
15,600 |
20,800 |
26,000 |
31,200 |
36,400 |
41,600 |
| 10,400 |
20,800 |
31,200 |
41,600 |
52,000 |
62,400 |
72,800 |
83,200 |
| 15,600 |
31,200 |
46,800 |
62,400 |
78,000 |
93,600 |
109,200 |
124,800 |
|
| |
Select
for information on Specifications for Auto-Series Sterilizer
Select for information on
Installation Specifications Auto-Series Sterilizer/Compactor |
|