EXTERIOR
DIMENSIONS:
Width: 87"
Length: 195"
Frame Height: 96"
Load Height: 103"
Overall Height (with door open): 183"
STERILIZER
SPECIFICATIONS:
Hourly
Capacity: 1,000 Lbs./Hour Medical
Chamber Volume Size: 8 cubic yards
Complete Cycle Time:
44 Minutes
Sterilize Cycle Time: 30 Minutes
Operating Temperature: 250°F to 285°F (application
dependent)
Vacuum Performance: + 12" hg
Control System: Programmable logic controller (P.L.C.)
Chamber Construction Material: ASME Code 240 316L
stainless steel
NOTE:
Performance parameters may be site specific.
UTILITY
CONSUMPTION AND OPERATING REQUIREMENTS:
Electrical: 208V, 240V, 330V, 480V, or 550V, 3Phase
(2 HP to 10 HP, depending on system configuration)
Control Voltage: 120 Volt, 1 Phase, 10 Amp Service
Steam @ Maximum Load: 400 Lbs. Per Cycle (includes
heat loss)
Steam Pressure Requirement: application dependent,
but generally 65 psig at San-I-Pak connection - 1-1/4"
NPT (NOTE: Vacuum Pump Needed
for Less Than 55 PSI Steam Supply)
Water: Normal city water pressure is acceptable -
1" NPT, 30-60 psig
Drain: Sanitary drain - 4"
STANDARD
EQUIPMENT:
PLC
Controlled System with Telemetry.
Automatic Time and Temperature Recorded Equipment.
Steam Ejector
Stainless Steel, Anti--Corrosive Construction
Self Closing & Locking Sterilizer Door
Auto Dumping
OPTIONAL
EQUIPMENT:
In-House
Monitoring Package (PC Interface)
Auto-Loading
Shredding (Single Stage or Multiple Stage)
Various Handling Systems
NOTES:
1. All controls and enclosures are U.L. Listed.
2. The sterilizer pressure vessel is A.S.M.E. certified.
3. When considering air flow engineering in an enclosed
processing room, 10 air changes per hour represents
typical recommendation.
|