San-I-Pak's
Patented Mark Series combines a high vacuum steam
sterilizer and a high intensity compactor into one
compact unit. This unique system allows for processing
of both infectious waste and general waste streams.
The Mark Series requires less space than other systems
and it can be configured to meet the needs of facilities
with little space available for a system. The unit
can be ground mounted or configured off a dock.
|
| |
|
| Mark
II-N Sterilizer/Compactor
(Mark II-N Shown in Off-Dock
Configuration) |
 |
|
Sterilizer
Specifications:
Chamber Capacity Per Hour: 106 lbs.
Chamber Size: 32" I.D. x 40" L
Cycle Time: 48 minutes ( vacuum, sterilization &
discharge)
- 8
Hour Shift = 848 lbs.
- 16
Hour Shift = 1,696 lbs.
- 24
Hour Shift = 2,544 lbs.
Compactor
Specifications:
Size:
1.2 cubic yards
Capacity/Hour: 1,440 lbs.
Loading Time: 5 minutes/cycle
Cycle Time: 40 seconds/cycle
Compaction Ratio: 4:1
- 8
Hour Shift = 11,520 lbs.
- 16
Hour Shift = 23,040 lbs.
- 24
Hour Shift = 34,560 lbs
|
Select
for information on Specifications for Mark II-N Sterilizer/Compactor
Select for information
on Installation Specifications for Mark II-N Sterilizer/Compactor |
| |
|
| Mark
VI-N Sterilizer/Compactor (Mark VI-N Shown
in Ground Mount Left Handed Configuration) |
 |
|
Sterilizer
Specifications:
Chamber Capacity/Hour: 200 lbs.
Chamber Size: 38" I.D. x 46" L
Cycle Time: 48 minutes ( vacuum, sterilization & discharge)
- 8
Hour Shift = 1,600 lbs.
- 16
Hour Shift = 3,200 lbs.
- 24
Hour Shift = 4,800 lbs.
Compactor
Specifications:
Size:
2.5 cubic yards
Capacity/Hour: 3,000 lbs.
Loading Time: 5 minutes/cycle
Cycle Time: 33 seconds/cycle
Compaction Ratio: 6:1
- 8
Hour Shift = 24,000 lbs.
- 16
Hour Shift = 48,000 lbs.
- 24
Hour Shift = 72,000 lbs.
|
Select
for information on Specifications for Mark VI-N Sterilizer/Compactor
Select for information on Installation
Specifications for Mark VI-N Sterilizer/Compactor |
| |
|
| Mark
VII-N Sterilizer/Compactor (Mark VII-N
Shown in Ground Mount Right Handed Configuration) |
 |
|
Sterilizer
Specifications:
Chamber Capacity/Hour: 400 lbs.
Chamber Size: 38" I.D. x 46" L (two chambers)
Cycle Time: 48 minutes ( vacuum, sterilization & discharge)
- 8
Hour Shift = 3,200 lbs.
- 16
Hour Shift = 6,400 lbs.
- 24
Hour Shift = 9,600 lbs.
Compactor
Specifications:
Size:
3.2 cubic yards
Capacity/Hour: 6,000 lbs.
Loading Time: 5 minutes/cycle
Cycle Time: 60 seconds/cycle
Compaction Ratio: 6:1
- 8
Hour Shift = 48,000 lbs.
- 16
Hour Shift = 96,000 lbs.
- 24
Hour Shift = 144,000 lbs.
|
Select
for information on Specifications for Mark VII-N Sterilizer/Compactor
Select for information on Installation
Specifications for Mark VII-N Sterilizer/Compactor |
| |
| |
Select
a Sterilizer Series for Detailed Specifications:
2P-Series I 3P-Series
I Auto-Series I Mark-Series I
Source-Series I CAT-Series
I AT-Series |
| |
|
|
More
Products:
Sterilizers
| Compactors | Shredders
| Optional Equipment
Handling Equipment | Sterilizer
Supplies
Select
for Information on Quality Assurance & Equipment Warranty
Select for Information on Value-Add Equipment & Services
Select
for Client Reference
|
|