STERILIZER
SPECIFICATIONS
Capacity Per Hour: 400 lbs.
Capacity Per 8 Hour Shift: 3,200 lbs.
Chamber Load Density: 150 lbs./yard
Chamber Size (per
chamber): 38" I.D. x 46" L.
Cycle Time: 48 minutes
Operating Temperature: 270°F - 283°F
Chamber Vacuum: 20+ inch Hg
Loading Height: 55 1/2"
|
COMPACTOR
SPECIFICATIONS
Charge Box Capacity: 3.2 cu. yds.
(manufacturers
rating)
Clear Top Opening: 60" W x 93" L
Capacity Per Hour: 6,000 lbs. minimum
Capacity Per 8 Hour: Shift 48,000 lbs. min.
Loading Height: 41"
Cycle Time: 60 seconds
|
| |
|
|
UTILITY
CONSUMPTION
Steam (min.
inlet: 60 lbs. PSI): 120 Lbs./Hr.
Steam maximum flow rate: 300 Lbs./Hr.
Electrical (all
voltages available): 3 Phase
(1.87 KWH @ 25% Duty Cycle of Compactor)
Electrical Control Voltage: 120 or 220 VAC
Water: 3 GPM (normal
city water pressure)
|
COMPACTOR
PERFORMANCE
Total Normal Force: 51,000 Lbs.
Total Maximum Force: 56,000 Lbs.
Normal Ram Face Force Rating: 35 PSI
Maximum
Ram Face Force: 39.24 PSI
Ram Penetration: 18.5 inches |
| |
|
|
STANDARD
EQUIPMENT
Strip Printer & Digital Display
Container 80% Full & 100% Full Indicator
Self Diagnostic P.L.C.
Steam Ejector Vacuum
|
ELECTRICAL
EQUIPMENT SPECIFICATIONS
Electric Motor: 10 Hp (all
3 ph voltages are available)
Electric Control Voltage: 120 or 220 VAC
UL
Label Panel Box: Nema Type |
| |
|
|
OPTIONAL
FEATURES AVAILABLE
Cart
Dumpers
Dual Controls for Remote Operation
Electric Steam Generator
Gas Fired Steam Boiler
Liquid Ring Vacuum Pump
Heavy Duty Steam Wash Down Kit
Elevated Machine Stands
Elevated Load Platforms
Top Loading Chutes
Lighting Package
|
HYDRAULIC
EQUIPMENT SPECIFICATIONS
Hydraulic Pump Capacity: 25 gpm
Normal Pressure: 1800 PSI
Maximum Pressure: 2000 PSI
Hydraulic
Cylinder: 6" bore, 115"
stroke
(telescopic cylinder)
CONCRETE
PAD REQUIREMENTS
6" - 3000# PSI Concrete
6 - 6" x 3/4" Anchor Bolts
|
| |
|
This
equipment conforms to all applicable ANSI Z 245.1-1984
Safety Standards.
The sterilizer pressure vessel is built to A.S.M.E.
specifications and certified by CAL OSHA. |